TCAT-2 Temperature Controller

Model:TCAT-2

 TCAT-2 Temperature Controller "Animal Temperature Controller"

  • Details
  • Specifications
  • Applications
  • Support
  •  TCAT-2 Temperature Controller with RET-3 Temperature probe and HL-1, Heat Lamp

    Our new TCAT-2 family of general purpose PID Autotuning Controllers provides accurate temperature control in a variety of laboratory applications. Combined with a heat lamp or heating pad, the TCAT-2 may be used to maintain the body temperature of anesthetized animals during surgery or stereotaxic procedures. Small animal cages are easily warmed with a heat lamp. The TCAT-2 may also be used in cooling applications, such as to control independent perfusate cooling systems. Realizing that laboratory applications are diverse, Physitemp can provide several versions of the TCAT Controller. The model specified depends on whether a laboratory has a general or specific need for the controller:

    TCAT-2AC:
    This version controls only AC powered heating or cooling devices such as a heat lamp. It is the least costly.

    TCAT-LV:
    This model provides a low-voltage DC output for electrically sensitive applications where AC frequencies might interfere with other monitoring devices. It comes standard with a built in DC power supply designed to operate with our HP-1M Heating Plate for small rodents. The TCAT-2LV utilizes a dual set point control circuit to prevent a heating element from overshooting the control point due to thermal lag in the control system. This is an important feature in preventing burns due to incorrect control settings or faulty feedback sensor. On a custom basis, we can provide a variety of DC power supplies Depending on the load power requirements.

    TCAT-2DF:
    This is a combination version which includes both an AC outlet for controlling primarily resistance loads such as heat lamps, AC powered warming blankets and a low-voltage, low-noise" DC output for heating pads. This version allows you to control a variety of different loads.

    All TCAT-2 versions may be used with any of our extensive line of accurate Type T thermocouple probes, which act as the temperature feedback sensor. Most commonly used are the RET series of animal rectal probes, but the IT series of implantable flexible probes and MT series of needle probes may also be used depending on the specific application. All instruments are designed to operate on a 110V or 230V AC supply.

    The unit comes in a durable baked enamel painted aluminum housing. Adjustable front feet allow the user to raise the front of controller to provide a more convenient viewing angle.

    A heat/cool switch is provided when using the controller with cooling devices such as small refrigeration compressors or thermoelectric stages. In the cooling mode it inverts the control function and shuts off the load when feedback sensor temperature falls below the set point. A small lamp on the front of the control unit indicates when power is being applied to the load.

    The TCAT-2 is simple to set-up; connect the feedback sensor to the animal and to the back of the controller, connect the heating pad, blanket, lamp or cooling device to the appropriate outlet on the rear of the controller. Adjust the set temperature as required (lower green display) according to the instruction label on top of the instrument. The set temperature is stored in memory after the unit is switched off.

    Features

    Controls heating blankets heat lamps or heating pad.

    Can be used for both heating and cooling applications.

    110 to 230V AC line operation

    Control Range of -100 to +400°C

    Resolution 0.1°C

  •  

     

    Specifications

    Resolution

     

    ±0.1°C

    Accuracy

     

    ± 0.5°C

    Range

     

    Ambient +2° to 60°C

    Readout

     

    Dual display of Set (red) and Run(red) temperatures

    Max AC Power Output with resistive load

     

    700 watts (Does not apply to TCAT-2LV)

    DC Output Rating:

     

    TCAT-2DF and TCAT-2LV: 12V DC, 2 Amps Max. Custom output voltages available upon request(Does not apply to TCAT-2AC)

    AC ground leakage current

     

    less than 1 millamp at 110 V AC

    Dual Setpoint Protection Feature

     

    TCAT-2DF and TCAT-2LV onlyadditional heating pad feedback sensor prevents temperature exceeding 45°C.

    Dimensions

     

    7 1/4" W x 4 3/8" H x 10" D

    Weight

     

    Less than 5 lbs.

    Power Supply

     

    110V or 220 V AC

  •  Please call for details 

  •  Please call for details 

ICP備案號: 滬ICP備15057650號-1 滬公網安備31011202005471
雷萌生物科技(上海)有限公司 保留所有版權.

首頁   |   產品中心   |   產品應用   |   技術支持   |   新聞中心   |   關于我們   |   ibidi官網
主站蜘蛛池模板: 精品麻豆丝袜高跟鞋av| 爽到高潮无码视频在线观看| 国产夫妇肉麻对白| 日韩人妻无码免费视频一二区| 欧美国产成人精品二区芒果视频| 99久久国语露脸精品国产色| 免费无码黄网站在线看| 97久久精品无码一区二区天美| 国产三级在线观看免费| 无码国产福利av私拍| 国产色视频网站免费| 国产亚洲精品第一综合| 欧美国产日韩亚洲中文| 9 9久热re在线精品视频| 亚洲人亚洲人成电影网站色| 精品免费国产一区二区| 欧美国产日韩久久mv| 精品国产av色欲果冻传媒| av无码精品一区二区三区四区| 韩国乱码片免费看| 182tv午夜福利在线地址二| 天天做日日做天天做| 久久无码无码久久综合综合| 人妻少妇乱子伦精品| 国产午夜福利精品久久2021| 秋霞无码久久久精品交换| 中文字幕久久精品波多野结百度| 97夜夜澡人人爽人人模人人喊| 女m羞辱调教视频网站| 国产在线无码视频一区二区三区 | 亚洲国产成人精品青青草原| 久久毛片免费看一区二区三区 | 国产偷久久久精品专区| 亚洲精品成人av观看| 2021久久精品国产99国产精品| 国产美女遭强高潮开双腿| 精品国产一区二区三区不卡在线| 精品无码人妻夜人多侵犯18| 五月丁香激激情亚洲综合| 免费无码久久成人网站入口| 中文字幕无码人妻丝袜|